Fire Suppression System

 

DCP-SOM-A/-AI - CLASS A SUPERVISED OUTPUT MODULE

STANDARD FEATURES

 

 

  • Built-in SCI circuitry (SOM-AI only)
  • Flexible application
  • Quick response to emergency conditions
  • Operation parameters are maintained by the module, and individual communication with the control system during emergency conditions is not required
  • Contacts are rated 2.0 Amps @ 24VDC
  • Programming is highly flexible providing 16 priority states plus zoning capability
  • Programmed device output is turned off, silenced, or programmed to output the selected pattern
  • UL 864 Listed

 

DESCRIPTION

 

The Class A Supervised Output Modules (DCP-SOM-A & SOM-AI) have been designed to provide application flexibility and quick response to emergency conditions. Flexibility is provided by a wide range of operating modes, including supporting multi-zone operations, and/ or functions, up to 16 different modulation patterns and multi-state programming. The operating parameters for the DCP-SOM-A & -AI are maintained by the module and do not require individual communication with the control system during emergency conditions to operate. The control panel simply broadcasts system conditions on the Signaling Line Circuit (SLC) and the DCP-SOM-A

  1. -AI modules do the rest based upon the custom configuration. Each DCP-SOM-A & -AI provides a single Class B or Class A circuit rated for 2.0 Amps @ 24 VDC. Each DCP-SOM-A & -AI also requires a 24 VDC power source in addition to the SLC.

SPECIFICATIONS

 

Supply Voltage (S-SC)

25.3 ~ 39 VDC

 

 

Auxiliary Supply Voltage

24 VDC

 

 

Average Current Consumption

 

 

SOM-AI - 420μA (Typical), SOM-A - 220μA (Typical) (on S-SC Line) Maximum 6mA: Red Alarm LED On

Current Consumption on

 

 

Auxiliary Power Lines

 

Typical 50μA

SCI On Resistance

 

 

40m ohm Max. (Normal Condition)

 

 

 

SCI Fault Detection Threshold

12 volts (Typical)

 

 

 

SCI Isolation Current

 

 

(Short Circuit Condition)

 

10mA (Typical)

 

 

 

Maximum Quantity Per Loop

127

Dimensions

4.2"W x 4.7"H x 1.4"D

 

 

 

Ambient Temperature

32°F (0°C) ~ 120°F (49°C)

 

 

 

Mounting

4" square electrical box

Maximum Output Current

2A@24VDC power limited

 

 

 

Relative Humidity

90% RH Non-condensing