Fire Suppression System
STANDARD FEATURES
Analog design using Hochiki’s advanced DCP protocol for fast and robust communication
Up to 127 sensors & modules, plus 127 analog sounder bases, for a total of 254 points possible per loop
Uses standard wire, no-shielded or twisted pair required on SLC loops
Integrated digital alarm communicator (DACT) with Contact ID and SIA reporting formats (optional)
Programmable sensitivity levels by device Alarm verification feature
Automatic daily calibration & drift compensation routine Large 8-line x 40-character LCD (320 char.)
1 SLC (2nd SLC optional)
RS-485 bus for panel networking (option)
Built-in RS-232 interface for programming via a PC
3 on board programmable Form C relays rated at 1 amp at 30VDC
2 auxiliary power outputs, each rated 360mA at 24 VDC
Loop Explorer Windows® configuration utility Auto-learn feature
500 network wide software zones
Network capability of up to 64 panels (option) Built in help and alarm information screens
2 on-board Class B (style Y) NAC circuits rated at 2.3 amps each (special application) and 1.6 amps each (regulated continuous)
Gentex, System Sensor, Wheelock, and Amseco NAC sync protocol built-in
Automatic day/night sensitivity modes Fire Drill test function
Walk test function
Powerful & versatile Cause & Effect wizard including:
- Disable function configuration
- Test mode configuration Seismic certified
DESCRIPTION
The FireNET Plus® 1127 series control panel is an analog addressable fire alarm panel with build options containing 1 or 2 SLC loops, a Digital Alarm Communi-cator/Transmitter (DACT), and an RS-485 bus for network communication. Each SLC loop supports 127 devices of any combination (sensors or modules), and 127 analog sounder bases, for a possible total of 254 points per loop. Communication between devices is accomplished by use of standard cable (shielded or twisted pair is not required). Each panel includes a 4-amp power supply and has 2 onboard NAC circuits. The RS-485 bus provides communication to the panel network while another RS-485 bus provides communi-cation for peripheral devices. The RS-232 interface allows the convenience of programming via a PC.
The system will support a variety of Hochiki devices such as photo, ion and heat sensors, which contain a unique, patented sensor design incorporating automatic drift compensation and day/night sensitivity modes. Additional devices include contact monitors, relay con-trollers, supervised auxiliary output and short circuit isolator modules. In addition, interfaces to conventional detection systems can be established by using a con-ventional zone-monitoring module.
The Loop Explorer Windows® Software interface pro-vides the installer with fingertip access to installation programming and diagnostic tools. An Auto Learn fea-ture offers the convenience for quick start applications. Add to this Hochiki's reputation for high quality and dedicated service, and you have an exceptional product with performance and value.
SPECIFICATIONS
Primary AC
120VAC @ 2.1 Amps 50/60hz or 220VAC @ 1.1Amps 50/60hz
Output DC
24VDC @ 5.25 Amps
Power Supply
4 Amp integrated
Charger Current
1.25 Amps max.
Dimensions
14.5” W x 19” H x 3.5” D
Weight
20 lbs. (without batteries)
Color
Red (optional gray)
Material
ABS/steel enclosure
Display
8 line x 40 character LCD (320 character total)
Network
Dual RS485 ports (64 panels max.)
Zones
500 network wide software zones per system
SLC loops
1 or 2 (class A, “style 6 or 7” or class B, “style 4”)
Devices per loop
127 sensors & modules, plus 127 analog sounder bases, 254 total
Addresses per panel
800 addresses + sub-addresses max. per panel
NAC Outputs
(2) class B, 2.3 Amps (special application)
1.6 Amps Regulated (continuous)
Relay Outputs
(3) Form C 1 Amp @ 30VDC
Aux. Power
2 outputs, 360mA @ 24VDC each
PC Port / Printer
RS232
DACT Formats
Contact ID and SIA
SLC COMPATIBLE DEVICES & SYSTEM ACCESSORIES
MODEL
DESCRIPTION
CONTROL PANEL EXPANDERS
FNP-1127-SLC
SLC One Loop Expansion Card
FN-4127-NIC
Network Interface Card
FN-4127-IO
16 Channel Input/Output Board
ANNUNCIATOR
FN-LCD-S
Serial LCD Annunciator
FNP-LED
Graphix Display
SLC LOOP DEVICES
ALG-V, ALK-V, ALN-V
Analog Addressable Photoelectric Sensor
AIE-EA
Analog Addressable Ionization Sensor
ATG-EA, ATJ-EA
Analog Addressable Heat Sensor
ACA-V, ACC-V
Multi-criteria Sensor
NSA-4 & NSA-6
Four Inch Sensor Base and Six Inch Sensor Base
SCI-B4 & SCI-B6
Four Inch Short Circuit Isolator Analog Sensor Base & Six Inch
Circuit Isolator Analog Sensor Base
ASB
Analog Sounder Base
ASBL
Analog Low Frequency Sounder Base
DH-98A, DH-98AR
Analog Addressable Duct Detector Unit (DH-98AR and
DH-99A, DH-99AR
DH-99AR have relays built-in)
MS-RA, MS-RA/R, MS-KA/R
Remote Test Station for DH-98AR & DH-99AR
DCP-FRCME-M
Contact Monitoring Module (mini w/terminal blocks)
DCP-FRCME-P
Contact Monitoring Module (mini w/pigtail leads)
DCP-FRCME-4
Contact Monitoring Module (with faceplate/indicating LED)
DCP-FRCMA, DCP-FRCMA-I
Class A Contact Monitoring Module (FRCMA-I has built-in SCI)
DCP-DIMM
Dual Input Monitor Module (with faceplate/indicating LED)
DCP-CZM
Conventional Zone Module
DCP-R2M
Dual Relay Module
DCP-R2ML/H Series
Dual Relay Module (R2ML-I & R2MH-I has built-in SCI)
DCP-SOM
Supervised Output Module
DCP-SOM-A, DCP-SOM-AI
Class A Supervised Output Module (SOM-AI has built-in SCI)
DCP-SOM-R
Supervised Output Module for Releasing Pre-action System
DCP-SCI
Short Circuit Isolator Module
DCP-AMS Series
Addressable Manual Pull Station
ACCESSORIES
TCH-B100
Hand Held Programmer (portable device addresser)
FN-ACC
Battery/Accessory Enclosure (houses up to 33AH size batteries)
FNP-ETR
Enclosure Trim Ring for panel flush mount